You can configure IXIASOFT CCMS to
		send an email to the Reviewers assigned to a Collaborative Review when it is open and
		available in IXIASOFT CCMS Web.
		
			Note: This can be applied within a Hosted environment, but only within a test server.
			For the email notification to work, the trigger for the Collaborative
				Review must be enabled in the triggers.xml
				configuration file and the activity report must be configured in the Scheduler.
		 
		- 
				Expand the Content Store's Repository node and browse to
						/system/conf/ to locate the file.
			
- 
				Check out triggers.xml and
					open it for editing.
			
- 
				Locate the trigger for email notifications for the
					Collaborative Review. For example, find the following: 
				<!-- trigger that creates the tickets for email notifications when Collaborative Review is assigned -->
 
- 
				Remove the <!--comment tag
					before the<trigger>element and the-->comment tag after</trigger>to enable the trigger .For example:
					 <!-- trigger that creates the tickets for email notifications when Collaborative Review is assigned -->
<trigger apply-to="changeStatus" class="com.ixiasoft.cms.triggers.CreateTicketTrigger" name="mailTicket"
objtype="collaborative-review" schedule="after">
   <parameters>
      <param name="initial-status" value="Authoring:closed"/>
      <param name="end-status" value="Authoring:open"/>
   </parameters>
</trigger>
<trigger apply-to="assignTo" class="com.ixiasoft.cms.triggers.assignments.CreateTicket" name="mailTicket"
objtype="collaborative-review" schedule="after">
   <parameters>
      <param name="valid-status" value="Authoring:open"/>
   </parameters>
</trigger>
 
- 
				Save, close, and Check In the
					file.
			
- 
                Inform users of the changes. 
                The changes will
                    be applied automatically once users close and then reopen their CCMS Desktop. Users can also apply the
                    changes without restarting their CCMS Desktop by clicking . Additionally, have an administrator refresh IXIASOFT CCMS Web so that users will see the change
                    reflected there. 
- Optional: 
				Configure the activity report in the Scheduler, if it is not
					already configured.
				 For more information, see how to configure the DITACMSActivityReport job in the Installing CCMS Scheduler.  
- Optional: 
				Customize the email template used when the notification email
					is sent. 
				For more information, see how to customize the
					change_status_ticket.xsl template in the Installing CCMS Scheduler.